Design a fine-bubble diffused aeration system to meet an oxygen demand of 5,000 kg/d. The plant is located at an elevation of 610 meters (2,000 ft). There are two aeration basins with a total volume equal to 5,400 m3. Assume the alpha and beta coefficients for the diffusers are 0.35 and 0.95, respectively and use a temperature correction factor () of 1.024. The dissolved oxygen (DO) saturation concentration of water is 7.81 mg/L at sea level and 28∘C. A DO concentration of 2.0 mg/L is maintained in the aeration basins. The oxygen transfer efficiency is assumed to be 30%, since fine-bubble diffusers are being used. The side water depth of the aeration basin is 4.9 m with diffusers placed 0.5 m from the bottom of the tank. The atmospheric pressure at an elevation of 610 meters is 706 mm Hg. Assume that the specific weight of water is 9,810 N/m3. Determine:

a. Volumetric flow rate of the air (m3/min) to meet oxygen requirement of 5,000 kg per day.

b. Power required (kw) for centrifugal blowers.

Found something interesting ?

• On-time delivery guarantee
• PhD-level professional writers
• Free Plagiarism Report

• 100% money-back guarantee
• Absolute Privacy & Confidentiality
• High Quality custom-written papers

Related Model Questions

Feel free to peruse our college and university model questions. If any our our assignment tasks interests you, click to place your order. Every paper is written by our professional essay writers from scratch to avoid plagiarism. We guarantee highest quality of work besides delivering your paper on time.